Home > Enterprise Vault > Enterprise Vault The Enterprise Vault .directoryconnection Object Reported An Error

Enterprise Vault The Enterprise Vault .directoryconnection Object Reported An Error

Solution Uninstall the EV API and install the EV Binaries. If this completes successfully and the errors stop, the issue is resolved. The user may also have Orphaned shortcuts in the mailbox that need to be removed. Delete the original archive     d. The Accelerators rely on EV Indexing to perform Searches and require certain EV files be installed on the Accelerator Server to allow communication with the EV Indexing Server(s). this content

Create/Manage Case QUESTIONS? Thank You! System.IO.FileNotFoundException: Schema update failed: class in poss-superiors does not exist.   Log Name: Symantec Enterprise Vault Source: Accelerator Service Processor Event ID: 481 Level: Error Description: APP AT - Customer ID: The Archiving Task will finally report an event 8390 error and the affected mailbox will not be processed.

Create/Manage Case QUESTIONS? Close Sign In Print Article Products Article Languages Subscribe to this Article Manage your Subscriptions Problem During a 'Run Now' or a schedule run the Storage Online process (StorageOnlineOpns) will report Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? Article:000022072 Publish: Article URL:http://www.veritas.com/docs/000022072 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in

Comments: Captcha Refresh 查價網情報網生活網萬用網 ribbed vault相關關鍵字 輸入搜尋: 友站連結 批發王 vaultribbedtl 15 vaultvault 34max vault llc4183 enterprise vault cleary vault87 vaultdv700 disc vaultribbed groin vault x CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical Scroll down the list of services and verify that the Enterprise Vault services are started. If the services have not started and their "Startup Type" is set to "Automatic", check the Enterprise Vault Event Log for the the event. Reference LinksEvent ID 8390 appears in the

Veritas does not guarantee the accuracy regarding the completeness of the translation. Check the "Debug programs" privilege to determine if the Vault Service Account is listed in the "Security Setting".3.If the Vault Service Account (VSA) is not listed, look at the icon next This can be done by enabling the Delete Orphaned Shortcut option in the Mailbox Policy.  If the errors continue, continue to Step 4.  If the same issue occurs do the following:     https://www.veritas.com/support/en_US/article.000022072 Close Sign In Print Article Products Article Languages Subscribe to this Article Manage your Subscriptions Problem The Symantec Enterprise Vault Event logs are full of 13360, 8453 and 8390 errors

On the Accelerator Server logged in as the Vault Service Account (VSA): - Stop and Disable the EV Accelerator Manager Service (EVAMS).- Uninstall the EV API files.- Install the full EV CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical Apply solution in article TECH66934. Consequently, when a user attempts to access items or synchronize, the stored procedure GetObjectSecurity is executed and the original Archive ID could not be found in the EnterpriseVaultDirectory.dbo.Root table.

The most common method of accomplishing this is to install the EV Binary files, also known as EV Binaries, on the Accelerator Server. http://cuteme.com.tw/fd/13014+itunes+error+fix Close Sign In Print Article Products Article Languages Subscribe to this Article Manage your Subscriptions Problem When the Enterprise Vault (EV) API is installed on the Accelerator Server, Accelerator Searches It is possible that updates have been made to the original version after this document was translated and published. The error code was 0x80040e14V-437-8453 Type : ErrorEvent : 13360Source : Enterprise VaultCategory : Directory ServiceDescription: An error was detected while accessing the Vault Database 'EnterpriseVaultDirectory' (Internal reference: {CADODataAccess::ExecuteSQLCommand}Description:  he [Root] table

No Yes Did this article save you the trouble of contacting technical support? http://csimonitoring.com/enterprise-vault/enterprise-vault-error-502.php Click Finish to exit the wizard." screen, uncheck the 'Show configuration information' or 'Show information on configuring installed components' box and click on Finish.--- Reboot as prompted.- Start the EVAMS.The Accelerator Examples of these errors are logged in the Enterprise Vault Event Logs on the Accelerator Server are listed below. Sorry, we couldn't post your feedback right now, please try again later.

Terms of use for this information are found in Legal Notices.

Related Articles Article Languages x Translated Content Please note that this document is a translation from English, and may The SQL error being generated 0x80040e14 indicates that the  query is failing to return any results as one of the parameters is not found.  The Stored procedure is executed anytime a user Solution 1. have a peek at these guys Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES Services Overview

Create/Manage Case QUESTIONS? This will show the user in question.  The first course of action is to delete the Vault Cache and synchronize. CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical

Remove this folder or rename this folder. 3.

You may also refer to the English Version of this knowledge base article for up-to-date information. You may also refer to the English Version of this knowledge base article for up-to-date information. No Yes How can we make this article more helpful? AND 0x80040e2fInternal references:Error [0x80040e2f]{CDirectoryConnectionObject::UpdateExchangeMbxArchiveFolder} [.\DirectoryConnectionObject.cpp, lines {2917,2926,2928}, built Dec 11 16:18:57 2012]V-437-8390Type :        ErrorEvent :        13360Source :        Enterprise VaultCategory :    Directory ServiceDescription: An error was detected while accessing the Vault Database 'EnterpriseVaultDirectory' (Internal

Open an Outlook profile to the affected mailbox. 2. Locate the folder with an empty space as the foldername 3. The folder structure of the archive reported may become damaged creating the need to apply solution in article TECH66934 to rebuild the archive. Yes: My problem was resolved. http://csimonitoring.com/enterprise-vault/enterprise-vault-owa-403-error.php This operation can be performed by restarting the Enterprise Vault Admin Service or by rebooting the Enterprise Vault server.Resolution2 :click "Start" | "Programs" | "Administrative Tools" | "Services".

Thank You! Mount the PST and verify it contains all items with the proper folder structure     c. It is possible that updates have been made to the original version after this document was translated and published. The InstallShield Wizard has successfully installed Enterprise Vault.

Re-enable the user to create the new archive     e. Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? Disable the user from archiving and Export the archive to PST     b. Error Message Type : ErrorEvent : 8390Source : Enterprise VaultCategory : Migrator ServerDescription: The EnterpriseVault.DirectoryConnection object reported an error. 0x80040e14Internal references:Error [0x80040e14]{CDirectoryConnectionObject::GetArchiveOrArchiveFolderSecurity}V-437-8390  Type : ErrorEvent : 8453Source : Enterprise VaultCategory : Directory

Error Message [Log Name: Symantec Enterprise Vault] Source: Accelerator Service Processor Event ID: 93 Level: Error Description: APP AT - Customer ID: X - An error occurred while updating Vaults for Double click the "Debug programs" privilege and add the Vault Service Account to the security settings.4.After the "Debug programs" privilege has been restored to the Vault Service Account, all Enterprise Vault Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? Another method is to install the EV API on the Accelerator Server - this does not install the full EV Binaries but does install a subset of the EV Binary files.

Email Address (Optional) Your feedback has been submitted successfully! The search flags for the attribute are invalid. One common cause of this error frenzy is when the archive in question has been deleted and Vault Cache still exists on the user's workstation.