Home > Enterprise Vault > Enterprise Vault Error 41293

Enterprise Vault Error 41293

Contents

If using a custom encoder, be sure that the IsContentTypeSupported method is implemented properly. It is possible that updates have been made to the original version after this document was translated and published. And start the EV Indexing service.6. If changing the port of the conflicting application is not possible, the port of the EVIndexVolumesProcessor.exe can be change.  Login to affected Enterprise Vault (EV) server using Vault Service Account (VSA) credentials.Go to EV Installation directory check over here

Create/Manage Case QUESTIONS? No Yes How can we make this article more helpful? No Yes How can we make this article more helpful? No Yes Did this article save you the trouble of contacting technical support?

Enterprise Vault Indexing Service 41293

Veritas does not guarantee the accuracy regarding the completeness of the translation. NOTE: Do not delete any other virtual directories or application pools as doing so will damage the Enterprise Vault installation.  Using windows explorer, navigate to the Enterprise Vault installation Directory and Cause Affected scenario: The upgrade of Enterprise Vault (EV) server was aborted. Sorry, we couldn't post your feedback right now, please try again later.

Email Address (Optional) Your feedback has been submitted successfully! Solution This issue can be resolved by deleting or moving the corrupt repository.xml file away from Indexmetadata folder. Locking is either by default (overrideModeDefault="Deny"), or set explicitly by a location tag with overrideMode="Deny" or the legacy allowOverride="false".   Log Name:      Symantec Enterprise VaultSource:        Enterprise Copy the EVIndexing Folder located  %program files \Enterprisevault\EVIndexing from the similar EV Version.2.

Check the applicaitonHost.config file using the following steps (these are for the line 6 section): Navigate to: %windir%\system32\inetsrv\config\ Open 'applicationHost.config' in notepad or other similar text editorNavigate to the appropriate EVInstall log shows following text "OnAbort Ended" when upgrade has been aborted. Error Message The start of Enterprise Vault Indexing service fails popping up: "The Enterprise vault indexing service on local computer started and then stopped. https://www.veritas.com/support/en_US/article.TECH204416 Create/Manage Case QUESTIONS?

Solution This can be rectified by re-installing the indexing engine using the Indexing Redistributable supplied with the Enterprise Vault Install Media.  Stop the Enterprise Vault Indexing Service on the affected Enterprise Close Sign In Print Article Products Article Languages Subscribe to this Article Manage your Subscriptions Problem Enterprise Vault (EV) Indexing service fails to start with Event ID 41293 logged stating No Yes Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES Thank You!

Index Admin Service 41293

For more information about Symantec Enterprise Vault’s DTRACE Utility please see HOWTO57893.DTRACE the process EVIndexAdminService for no less than 5 minutes while re-creating the issue.Open the log file created and search No Yes How can we make this article more helpful? Enterprise Vault Indexing Service 41293 You may also refer to the English Version of this knowledge base article for up-to-date information. The Exception [rights-execute] Was Thrown No Yes Did this article save you the trouble of contacting technical support?

Solution   Error DescriptionArticleError with the Enterprise Vault Services after an uninstall of the Enterprise Vault Client from the serverTECH178024Event 41293, 40966 - Indexing service start up error: Missing metadata file TECH179842Events http://csimonitoring.com/enterprise-vault/enterprise-vault-error-500.php CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical For assistance, please contact Enterprise Vault customer support. (ID: CORE_LICENSE_NO_KEY)V-437-41293 Event ID: 41315 Task Category: Index Query Server Level: Warning Description: **** No Enterprise Vault License **** Please try to install your Veritas does not guarantee the accuracy regarding the completeness of the translation. Enterprise Vault Reset Indexing Engine

Event 41293 logged stating repository.xml file corrupt. The occurrence of this issue is rare.  Reset of Indexing engine generates error "Cannot Downgrade". Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? this content Before deleting the file, save the backup copy of the file outside the indexmetadata folder. 1.

V-437-41293 Cause This is an Internet Information Services (IIS) related error and is caused when the applicationHost.config file for the Enterprise Vault (EV) server has either the overrirdeModeDefault is set to Rebuilding.   (ID: XML_INDEX_CORRUPTED)

error (16 ms) - vivisimo_load|: Malformed XML file [C:\Program Files (x86)\Enterprise Vault\EVIndexing\data\indexmetadata\repository.xml] The remote server returned an error: (500) Internal Server Error. Locking is either by default (overrideModeDefault="Deny"), or set explicitly by a location tag with overrideMode="Deny" or the legacy allowOverride="false".

No Yes Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES

Following the re-installation of the Indexing Server, please ensure to reapply any hotfixes that were previously removed.  Restart the Enterprise Vault Indexing Service NOTE: It may take a while for the Error Message Event ID: 41293 Task Category: Index Admin Service Level: Error Description:**** No Enterprise Vault License **** Please try to install your license through the Index Engine Administration Tool. From command prompt, run iisreset /start4. No Yes Did this article save you the trouble of contacting technical support?

Error Summary: Indexing Service start up error Error Details: Filename: \\?\C:\Program Files (x86)\Enterprise Vault\EVIndexing\www\asp\web.configLine number: 15Error: This configuration section cannot be used at this path. No Yes Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES No Yes How can we make this article more helpful? http://csimonitoring.com/enterprise-vault/enterprise-vault-owa-403-error.php Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue?

Start the IIS Admin Service and World wide web publishing service OR run iisreset /start from command prompt.5. CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical No Yes How can we make this article more helpful? It is possible that updates have been made to the original version after this document was translated and published.

CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical If using a custom encoder, be sure that the IsContentTypeSupported method is implemented properly. Locate the installation msi used to install the hotfix b. Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES Services Overview

Create/Manage Case QUESTIONS? Create/Manage Case QUESTIONS? You may also refer to the English Version of this knowledge base article for up-to-date information. Sorry, we couldn't post your feedback right now, please try again later.

NOTE: In some cases, such as if Enterprise Vault is clustered, the IndexMetaData folder (which is usually found under the EVIndexing subdirectory) may be held in a different location and will Create/Manage Case QUESTIONS? Veritas does not guarantee the accuracy regarding the completeness of the translation. Sorry, we couldn't post your feedback right now, please try again later.

Email Address (Optional) Your feedback has been submitted successfully!